This specification covers the requirements for stainless steel bolts, hex cap screws, and stud bolts in imperial size 0.25 inch to 1.50 inch, inclusive for number of alloys in common use and intended for service applications requiring general corrosion resistance. ASTM F593 covers seven groups of stsinles steel alloys, including twelve austenitic, two ferritic, four martensitic and one precitipitain hardening. BoltPort manufactures all alloys under ASTM F593 in form of Hex Bolts, Stud Bolts, Threaded Rods, Socket Head Cap Screws duly tested and supply with EN 10204 Type 3.1 Certification.
Group | AlloyA | Condition Furnished Unless Otherwise Specified |
---|---|---|
1 | 303, 303Se | (CW) Cold WorkedB |
A Unless otherwise specified on the inquiry and order, the choice of an alloy from within a group shall be at the discretion of the fastener manufacturer
B Sizes 0.75 inch and larger may be hot worked and solutoon annealed.
A - Machined from annealed or solution annealed stock thus retaining the properties of the original material; or hot formed and solution annealed.
AF - Headed and rolled from annealed stock and then reannealed
CW - Headed and rolled from annealed stock thus acquiring a degree of cold work. Sizes 0.75inch and larger may be hot worked and solution annealed.
SH - Machined from strain hardened stock or cold worked to develop the specific properties.
Composition, %, maximum except as shown | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
UNS Designation | Alloy Group | Alloy | Carbon | Manganese | Phosphorus | Sulfur | Silicon | Chromium | Nickel | Molybdenum | ||
S30300 | 1 | 303 | 0.15 | 2.00 | 0.200 | 0.150 min | 1 | 17.0 - 19.0 | 8.0 - 10.0 | 0.60 maxA |
A At manufacturer's options, determined only when intentionally added.
ConditionB | Alloy Mechanical Property Marking | Nominal Diameter, inch | Full Size Tests | Machined Specimen Tests | ||||
---|---|---|---|---|---|---|---|---|
Tensile Strength, ksiC | Yield Strength, ksiDC | Rockwell Hardness | Tensile Strength, ksiC | Yield Strength, ksiDC | Elongation in 4D, % | |||
AF | F593A | 1/4 to 1-1/2, incl. | 65 - 85 | 20 | B85 max | 60 | 20 | 40 |
A | F593B | 1/4 to 1-1/2, incl. | 75 - 100 | 30 | B65 to 95 | 70 | 30 | 30 |
CW1 | F593C | 1/4 to 5/8, incl. | 100 - 150 | 65 | B95 to C322 | 95 | 60 | 20 |
CW1 | F593C | 1/4 to 5/8, incl. | 100 - 150 | 65 | B95 to C322 | 95 | 60 | 20 |
CW2 | F593D | 3/4 to 1-1/2, incl. | 85 - 140 | 45 | B80 to C32 | 80 | 40 | 25 |
SH1 | F593A | 1/4 to 5/8, incl. | 120 - 160 | 95 | C24 to C36 | 115 | 90 | 12 |
SH2 | F593B | 3/4 to 1, incl. | 110 - 150 | 75 | C20 to C32 | 105 | 70 | 15 |
SH3 | F593C | 1-1/8 to 1-1/4, incl. | 100 - 140 | 60 | B95 to C30 | 95 | 55 | 20 |
SH4 | F593D | 1-3/8 to 1-1/2, incl. | 95 - 130 | 45 | B90 to C28 | 90 | 40 | 28 |
A Minimum values except where shown as maximum or as a range.
B legend of conditions:
AF - Headed and rolled from annealed stock and then reannealed
CW - Headed and rolled from annealed stock thus acquiring a degree of cold work. Sizes 0.75inch and larger may be hot worked and solution annealed.
SH - Machined from strain hardened stock or cold worked to develop the specific properties.
C The yield and tensile strength values for full size products shall be computed by dividing the yield and maximum tensile load value by the stress area for the product size and thread sizes determined in accordance with Test Methods F606.
D Yield strength is the stress at which an offset of 0.2 & gauge length occurs.
Item | Nominal Length | Tensile Load, lbf | Full Size Tests | Machined Specimen Tests | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Diameters 3/4 inch and Less | Diameters Over 3/4 inch. | Wedge Tensile Strength | Axial Tensile Strength | Yield Strength | Rockwell Hardness | Tensile Strength | Yield Strength | Elongation | ||
Hex head, square head and hex socket cap screws | Less than 2-1/4 D | Less than 3D | all | Option A | Option B | B | Option C | B | B | B |
2-1/4 D and longer | 3D and longer | 120 000 max | Mandatory | B | Mandatory | B | B | B | B | |
2-1/4 D and longer | 3D and longer | over 120 000 | Option A | B | Option A | B | Option B | Option B | Option B | |
Stud bolts and other bolts | Less than 2-1/4 D | Less than 3D | all | B | Option A | B | Option B | B | B | B |
2-1/4 D and longer | 3D and longer | 120 000 max | B | Mandatory | Mandatory | B | B | B | B | |
2-1/4 D and longer | 3D and longer | over 120 000 | B | Option A | Option A | B | Option B | Option B | Option B | |
SpecialsC | all | all | all | B | B | Mandatory | B | B | B | B |
A Where options are given, all the tests under an option shall be performed. Option A, Option B and Option C indicates manufacturer may perform all Option A (full-size), all Option B (machined specimen), or all Option C tests whichever is preferred. Option A tests should be made whenever feasible.
B Tests that are not mandatory
C Special fasteners are those fasteners with special configurations including drilled heads, reduced body, etc., that are weaker than the threaded section. Special fasteners have full size heads shall be tested as specified for stud bolts and other bolts.
Nominal Size, inch. | Coarse Threads - UNC | Fine Threads - UNF | Thread Series - 8UN | |||
---|---|---|---|---|---|---|
Threads / inch | Stress AreaA, in2 | Threads / inch | Stress AreaA, in2 | Threads / inch | Stress AreaA, in2 | |
1/4 | 20 | 0.0318 | 28 | 0.0364 | -- | -- |
5/16 | 18 | 0.0524 | 24 | 0.0580 | -- | -- |
3/18 | 16 | 0.0775 | 24 | 0.0878 | -- | -- |
7/16 | 14 | 0.1063 | 20 | 0.1187 | ||
1/2 | 13 | 0.1419 | 20 | 0.1599 | ||
9/16 | 12 | 0.1820 | 18 | 0.2030 | ||
5/8 | 11 | 0.2260 | 18 | 0.2560 | ||
3/4 | 10 | 0.3340 | 16 | 0.3730 | ||
7/8 | 9 | 0.4620 | 14 | 0.5090 | ||
1 | 8 | 0.6060 | 12 | 0.6630 | ||
1 1/8 | 7 | 0.7630 | 12 | 0.8560 | 8 | 0.790 |
1 1/4 | 7 | 0.9690 | 12 | 1.0730 | 8 | 1.000 |
1 3/8 | 6 | 1.1550 | 12 | 1.3150 | 8 | 1.233 |
1 1/2 | 6 | 1.4050 | 12 | 1.5810 | 8 | 1.492 |
A Tensile stress areas are computed using the following formula:
AB = 0.7854 [D- (0.9743/n)]2